Szerző szerinti böngészés "Hamidli, Narmin"
Megjelenítve 1 - 6 (Összesen 6)
Találat egy oldalon
Rendezési lehetőségek
Tétel Szabadon hozzáférhető Analysis of intact proteins with capillary zone electrophoresis coupled to mass spectromery using uncoated and coated capillaries(2021) Hamidli, Narmin; Andrási, Melinda; Nagy, Cynthia; Gáspár, AttilaTétel Szabadon hozzáférhető Determination of deamidated isoforms of human insulin using capillary electrophoresis(2020) Andrási, Melinda; Pajaziti, Blerta; Sipos, B.; Nagy, Cynthia; Hamidli, Narmin; Gáspár, AttilaTétel Szabadon hozzáférhető Determination of human insulin and its six therapeutic analogues by capillary electrophoresis - mass spectrometry(2022) Hamidli, Narmin; Pajaziti, Blerta; Andrási, Melinda; Nagy, Cynthia; Gáspár, AttilaTétel Szabadon hozzáférhető Intact protein analysis using capillary zone electrophoresis-mass spectrometry in different capillariesHamidli, Narmin; Gáspár, Attila; Kémiai Tudományok Doktori Iskola; Debreceni Egyetem::Természettudományi és Technológiai Kar::Kémiai Intézet::Szervetlen és Analitikai Kémiai TanszékIn this work, the performance of bare fused silica (BFS) capillary for intact protein analysis was compared to that of different (dynamically coated polybrene (PB) and permanently coated linear polyacrylamide (LPA)) coated capillaries using capillary zone electrophoresis - mass spectrometry (CZE-MS). In cases where low pH (pH=1.8) was used in bare silica capillaries for the separation of 5 destinct proteins, good precision (0.56-0.78 RSD% and 1.7-6.5 RSD% for migration times and peak areas, respectively), minimal adsorption and separation efficiency (N= 27 000/m -322 000/m) similar to or even better than those obtained with the coated capillaries was achieved. The PB and the LPA capillaries demonstrated their slightly better resolving power in terms of separating the different forms/variants of the same protein (e.g., hemoglobin subunits). The examined CZE-MS methods has been optimized for the separation of human insulin and its 6 analogues, where 3 layer PB-coated (PB-DS-PB) capilaries have exhibited the highest number of theoritical plates, resolution and precision data. A broader application areas of CZE-MS have also been explored by the application of the new methods for the separation of desamido insulin forms, native proteins and monoclonal antibody.Tétel Szabadon hozzáférhető Study of effect of incubation time and temperature on the linear polyacrylamide-coating performance for the separation of proteins by capillary zone electrophoresis(2023) Andrási, Melinda; Zagyi, Bálint; Hamidli, NarminTétel Szabadon hozzáférhető Top-down proteomic analysis of monoclonal antibodies by capillary zone electrophoresis-mass spectrometry(2022) Nagy, Cynthia; Andrási, Melinda; Hamidli, Narmin; Gyémánt, Gyöngyi; Gáspár, Attila